2pcs N1201SA UV RF Vector Impedance Analyzer Accuracy Agility Instrument
Description:
– This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration
– The default boot into single-point measurement interface.
Startup and shutdown
– Hold down the CTRL key off press the power switch button.
– The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
– The boot state, long press (2S above) the switch button, after the release, the instrument will shut down
Advice when using:
– In order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
– Try to use good quality RF cable and connectors.
– Calibrated cable marked to the next may not need to calibrate and direct use.
– Test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
– Measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
– If the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis.
Specifications:
– Model: N1201SA
– Working currency: 137.5MHz~2700MHz
– Stepped frequency 1kHz
– Display 2.4inch TFT
– Resolution ratio 320*240(QVGA)
– Battery capacity: 2000mAH(7.4Wh)
– Power consumption <1.5W
– Charge current 400mA
– Charge port USB
– Auto power off can be set 5-60minutes
– Measured parameters resistence reactance standing wave s11
– Resolution ratio 4 number
– Frequency accuracy about 5ppm
– Connector SMA-K
– Impedance measurement range: 0.1~1000
– Standing wave measurement range:1.000~65
– S11(dB)measurement range: 0dB~-60dB
– Working temperature:0~40 degree
– Atmospheric pressure:860hPa~1060hPa
Package list:
2 x N1201SA UV RF Vector Impedance ANT SWR Antenna Analyzer Meter
Note:
For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
If any questions Or bulk order, please contact Ms. Amy Huang:
Email: mail@walkytalkyshop.com
WhatsApp / Skype: +86-13860123881
Tel: 86(592)5995025
Fax: 86(592)3720556
Reviews
There are no reviews yet.